SOP-SAL-01 to 03
Sales & estimation
- Every enquiry is registered once in our ERP, with its drawings and BOQ
- Costing is checked and the offer approved before it goes out
- The order is reviewed and handed to the factory with the approved scope
Powering
INDIA
APJ Engineers Pvt. Ltd. (formerly known as Ashok Prajapati & Co.) is a CPRI-tested and IEC 61439 certified manufacturer of LT/HT panels, acoustic enclosures, DG sets, cable trays, and compact substations based in Vasai, Maharashtra.
Comprehensive power distribution & infrastructure solutions from a single source.
PCC / MCC / APFC
11kV / 33kV VCB
CPCB II Compliant
15kVA - 3000kVA
11kV / 33kV Package
800A - 6300A
GI / SS / FRP
24/7 Support
About APJ Engineers · PDF, 8.4 MB
Download PDFCPRI / ERDA / ASTA
View CertificatesEvery enclosure is cut and bent on CNC machines in our own works, so parts fit first time and panels leave on schedule.
CRCA sheets cut straight from the CAD drawing: clean edges, cut-outs and louvres in one pass, with no punching or filing.
CNC Synchro bending with a programmed back gauge: every door, cover and frame bent to the same angle, batch after batch.
50,000 sq.ft. integrated facility at Palghar, Maharashtra
Precision CNC fiber laser cutting for CRCA sheets with ±0.1mm tolerance.
Superior corrosion resistance through automated hot degreasing, derusting, and zinc phosphating.
Conveyorised booth with Nordson electrostatic guns for 60-80μm uniform coating.
5000+ panels annually. 100% factory acceptance testing with Schneider & ABB components.
Pan-India logistics with on-site SITC and commissioning teams.
50,000 sq.ft. integrated facility at Palghar, Maharashtra. From raw sheet metal to commissioned panel, under one roof.
Our state-of-the-art CNC fiber laser cutting machines process CRCA sheets with unmatched precision, delivering clean edges and tight tolerances for every panel enclosure.
Our automated 9-tank pre-treatment line ensures superior corrosion resistance. Each panel body goes through hot degreasing, derusting, water rinsing, zinc phosphating and passivation, all with automated hoists.
Our conveyorised powder coating booth with Nordson electrostatic guns ensures uniform 60-80 micron coating thickness. RAL 7032 / 7035 standard finishes with custom colour options available.
Expert assembly by qualified technicians using high-grade busbars and components. 100% factory acceptance testing (FAT) for insulation resistance, high voltage, and function.
From our factory floor to your site: pan-India logistics with dedicated SITC teams for supply, installation, testing, and commissioning. Complete project handover with documentation.
Every department works to a written procedure that names its owner and the record it leaves in our ERP.

SOP-SAL-01 to 03

SOP-DES-01 to 03

SOP-PUR-01, 02 and SOP-STR-01 to 03

SOP-PRD-02 to 04

SOP-PRD-01, 05 and SOP-QA-01

SOP-QA-02, 03, 05

SOP-DSP-01, SOP-SRV-01, SOP-EHS-01
The checkpoints follow the panel type: PCC, MCC, APFC, AMF, bus duct, starter and more.
Incoming inspection
Material checked against the PO and BOM
Performed, reviewed
Fabrication & finish
Dimensions, busbars, coating thickness
Performed, reviewed
HOLD POINTAssembly & wiring
Devices, wiring and terminations to drawing
Performed, reviewed
HOLD POINTFactory acceptance test
Functional, IR and HV tests per IEC 61439-1
Performed, witnessed
HOLD POINTDocuments & dispatch
Released only after the FAT is passed
Performed, reviewed
Witnessed means by the client or a third-party inspector. Pictures are illustrations.
From approved drawing to site service, each step leaves a record in our ERP. Scan the QR on any APJ panel and see its history.
Witnessed & signed by our clients
Live from our ERP, as of .
Each row is a factory acceptance test attended by the client's side. Live from our ERP.
| Month | Panel | Rating | Witnessed by |
|---|
Given at sign-off by the people who witnessed the test.
Drawings approved
ECN log for every revision
Material GRN
Incoming inspection, stage A
Fabrication & coating
Hold point, stage B
Assembly & wiring
Hold point, stage C
FAT, IEC 61439-1
Routine verification, stage D
Dispatch
Released only after FAT pass
Site & service
SAT and service reports
Sales, design, purchase, stores, production, quality, dispatch, service and safety. Each SOP names its owner, the record it leaves and where that record lives.
See how we workFive QAP stages, A to E. The checkpoints follow the panel type: PCC, MCC, APFC, AMF, bus duct, starter and more. A panel moves on only when its stage is cleared.
See the five stagesIEC 61439-1 routine verification with test readings, the QAP results, photos and a test video. Each instrument used is listed with its calibration certificate.
The QC & SOP QR goes on after powder coating and shows the panel's QC and SOP record. The FAT QR opens the panel's FAT report, drawings, test video and site reports.
Commissioning (SAT), service and emergency visit reports are filed against the same panel, so its FAT QR shows the complete history. DG AMC sites get a report per visit plus quarterly reviews.
ASTA 6300 A / 85 kA, CPRI 4000 A / 65 kA, ERDA temperature rise, IP55 and IP65, and ASTA internal arc 85 kA. Boards are verified against the certificate that covers them.
Scan the FAT QR on the panel door, or type the code printed under it.
Receive APJ Engineers' contact and product catalog directly on your WhatsApp. Stay connected for instant quotes and support.
Opens WhatsApp with a ready message to +91 99677 17710. We reply with the full package.
APJ Engineers
lets Power up
APJ-Digital-Card.pdf
245 KB · PDF
Powering India's leading enterprises across critical sectors.